CVE-2018-1000634
The Open Microscopy Environment OMERO.server version 5.4.0 to 5.4.6 contains an Improper Access Control vulnerability in User management that can result in administrative user with privilege restri...
Affects 1 product across 1 vendor.
Software does not properly assign, modify, track, or check privileges, allowing unauthorized elevation of access.
Mapping is CWE-to-CAPEC per MITRE CAPEC 3.9.
This vulnerability was disclosed in 2018. A high severity vulnerability affects Openmicroscopy systems (CVE-2018-1000634). No public exploit code is currently available. Isolate affected systems if patching is not feasible.
BSID: BS-2018-GLOBAL-122355-H • Model: rule-based-v1 • Confidence: MEDIUM
Is this CVE in your environment?
BreachSpider monitors your ICS/OT environment for vulnerabilities like this one. No agents or network access required. Free to start.
Check My Environment →What is CVE-2018-1000634?
What is the CVSS score for CVE-2018-1000634?
Is CVE-2018-1000634 actively exploited?
How do I remediate CVE-2018-1000634?
What systems are affected by CVE-2018-1000634?
| CVE ID | CVE-2018-1000634 |
|---|---|
| BSID | BS-2018-GLOBAL-122355-H BreachSpider Global ID |
| CVSS Vector | CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H |
| Published | 2018-08-20 |
| Last Modified | 2024-11-21 |
| ICS Relevance | 15% |
| Weakness (CWE) | |
| Source | NVD |
The Open Microscopy Environment OMERO.server version 5.4.0 to 5.4.6 contains an Improper Access Control vulnerability in User management that can result in administrative user with privilege restrictions logging in as a more powerful administrator. This attack appear to be exploitable via Use user administration privilege to set the password of a more powerful administrator. This vulnerability appears to have been fixed in 5.4.7.
Source: NIST NVD / MITRE CVE Database
Vulnerability details: The Open Microscopy Environment OMERO.server version 5.4.0 to 5.4.6 contains an Improper Access Control vulnerability in User management that can result in administrative user with privilege restrictions logging in as a more powerful administrator. This attack appear to be exploitable via Use user administration privilege to set the password of a more powerful administrator. This vulnerability appears to have been fixed in 5.4.7. CVSS vector: CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H.
Exploitation Likelihood: MINIMAL
| Vendor | Product | Affected Versions |
|---|---|---|
| Openmicroscopy | Omero | ≥ 5.4.0, ≤ 5.4.6 |
| CISA known-exploited | Not in KEV catalog |
|---|---|
| Public Exploit | Not confirmed |
| PoC Code | Not confirmed |
AI Enrichment Record — provenance & audit hash
| Model | rule-based-v1 |
|---|---|
| Confidence | MEDIUM |
| Enriched At | 2026-05-24 |
| SHA-512 Audit Hash | ce45607ca5bd7cdbab76b68fbc568dafd16bb5efc1c0c59426a4e5550808cfdb56d66c2e211b9fadbc7798b53f89020e3fa336b50a875b176f3fd8a2d598bfca |
ICS/OT Vulnerability Intelligence for Your Environment
BreachSpider tracks 384,000+ CVEs and matches them to your ICS/OT assets by exact version, with AI analysis, NERC CIP mapping, and vendor PSIRT contacts.
Create a free account →