CVE-2019-14450
A directory traversal vulnerability was discovered in RepetierServer.exe in Repetier-Server 0.8 through 0.91 that allows for the creation of a user controlled XML file at an unintended location. Wh...
Affects 1 product across 1 vendor.
Attacker manipulates file path inputs to access files outside the intended directory.
Mapping is CWE-to-CAPEC per MITRE CAPEC 3.9.
This vulnerability was disclosed in 2019. A critical vulnerability affects Repetier-Server systems (CVE-2019-14450). A proof-of-concept has been published. Isolate affected systems if patching is not feasible.
BSID: BS-2019-GLOBAL-225436-C • Model: rule-based-v1 • Confidence: MEDIUM
Is this CVE in your environment?
BreachSpider monitors your ICS/OT environment for vulnerabilities like this one. No agents or network access required. Free to start.
Check My Environment →What is CVE-2019-14450?
What is the CVSS score for CVE-2019-14450?
Is CVE-2019-14450 actively exploited?
How do I remediate CVE-2019-14450?
What systems are affected by CVE-2019-14450?
| CVE ID | CVE-2019-14450 |
|---|---|
| BSID | BS-2019-GLOBAL-225436-C BreachSpider Global ID |
| CVSS Vector | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| Published | 2019-10-28 |
| Last Modified | 2026-06-17 |
| ICS Relevance | 15% |
| Weakness (CWE) | |
| Source | NVD |
A directory traversal vulnerability was discovered in RepetierServer.exe in Repetier-Server 0.8 through 0.91 that allows for the creation of a user controlled XML file at an unintended location. When this is combined with CVE-2019-14451, an attacker can upload an "external command" configuration as a printer configuration, and achieve remote code execution. After exploitation, loading of the external command configuration is dependent on a system reboot or service restart.
Source: NIST NVD / MITRE CVE Database
Vulnerability details: A directory traversal vulnerability was discovered in RepetierServer.exe in Repetier-Server 0.8 through 0.91 that allows for the creation of a user controlled XML file at an unintended location. When this is combined with CVE-2019-14451, an attacker can upload an "external command" configuration as a printer configuration, and achieve remote code execution. After exploitation, loading of the external command configuration is dependent on a system reboot or service restart. CVSS vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.
Exploitation Likelihood: MEDIUM
| Vendor | Product | Affected Versions |
|---|---|---|
| Repetier-Server | Repetier-Server | ≥ 0.80, ≤ 0.91 |
No official vendor advisory link on record. See the CVE record →
| CISA known-exploited | Not in KEV catalog |
|---|---|
| Public Exploit | Not confirmed |
| PoC Code | Not confirmed |
AI Enrichment Record — provenance & audit hash
| Model | rule-based-v1 |
|---|---|
| Confidence | MEDIUM |
| Enriched At | 2026-05-24 |
| SHA-512 Audit Hash | af746d74e9572719c72c7be3c445dbcbeee7df09e2ddc7649c2514ea097af3c33801da306d3d290c4519018a5357fd66e5b15d506947ce0522511a80e9aeae65 |
Critical Severity - Know Your Exposure
A CVSS 9.8 vulnerability in your ICS environment cannot wait. BreachSpider maps critical CVEs to your specific assets and tells you what to fix first.
Create a free account →