CVE-2022-28910
TOTOLink N600R V5.3c.7159_B20190425 was discovered to contain a command injection vulnerability via the devicename parameter in /setting/setDeviceName.
Affects 2 products across 1 vendor.
Attacker injects OS commands through application inputs passed to system() or equivalent calls, leading to arbitrary command execution.
Mapping is CWE-to-CAPEC per MITRE CAPEC 3.9.
TOTOLink N600R V5.3c.7159_B20190425 is vulnerable to a command injection attack through the devicename parameter in the /setting/setDeviceName endpoint, allowing an attacker to execute arbitrary commands with root privileges.
BSID: BS-2022-GLOBAL-317099-C • Model: /workspace/models/qwen2.5-coder-32b-instruct-bf16 • Confidence: HIGH
Is this CVE in your environment?
BreachSpider monitors your ICS/OT environment for vulnerabilities like this one. No agents or network access required. Free to start.
Check My Environment →What is CVE-2022-28910?
What is the CVSS score for CVE-2022-28910?
Is CVE-2022-28910 actively exploited?
How do I remediate CVE-2022-28910?
What systems are affected by CVE-2022-28910?
| CVE ID | CVE-2022-28910 |
|---|---|
| BSID | BS-2022-GLOBAL-317099-C BreachSpider Global ID |
| CVSS Vector | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| Published | 2022-05-10 |
| Last Modified | 2026-06-17 |
| ICS Relevance | 15% |
| Weakness (CWE) | |
| Source | NVD |
TOTOLink N600R V5.3c.7159_B20190425 was discovered to contain a command injection vulnerability via the devicename parameter in /setting/setDeviceName.
Source: NIST NVD / MITRE CVE Database
The vulnerability exists in the handling of the devicename parameter in the /setting/setDeviceName endpoint. An attacker can inject malicious commands into this parameter, which are then executed by the system with root privileges, leading to potential unauthorized access and control over the device.
Exploitation Likelihood: CRITICAL
| Vendor | Product | Affected Versions |
|---|---|---|
| Totolink | N600R (device & firmware) | 5.3c.7159_b20190425 |
No official vendor advisory link on record. See the CVE record →
| CISA known-exploited | Not in KEV catalog |
|---|---|
| Public Exploit | Not confirmed |
| PoC Code | Not confirmed |
AI Enrichment Record — provenance & audit hash
| Model | /workspace/models/qwen2.5-coder-32b-instruct-bf16 |
|---|---|
| Confidence | HIGH |
| Enriched At | 2026-05-24 |
| SHA-512 Audit Hash | 4cc3b9e93390ca44e07c88f2f288f75f02bd15209a4eeeec98d572cdbb160c06e821d8afcb39cb3e2cc2512999c8221bbb37acb9bc7c17cbbee929757c322768 |
Critical Severity - Know Your Exposure
A CVSS 9.8 vulnerability in your ICS environment cannot wait. BreachSpider maps critical CVEs to your specific assets and tells you what to fix first.
Create a free account →