CVE-2013-6920
Siemens SINAMICS S/G controllers with firmware before 4.6.11 do not require authentication for FTP and TELNET sessions, which allows remote attackers to bypass intended access restrictions via TCP ...
Affects 20 products across 1 vendor.
Software does not prove or insufficiently proves that the user is who they claim to be.
Show all 10
Mapping is CWE-to-CAPEC per MITRE CAPEC 3.9.
The Siemens SINAMICS S/G controllers with firmware versions prior to 4.6.11 are vulnerable to unauthorized access via FTP and TELNET services, allowing remote attackers to bypass authentication mechanisms and gain full control over the device. This vulnerability poses significant risks to operational integrity and security in industrial environments.
BSID: BS-2013-GLOBAL-096477-C • Model: Qwen/Qwen2.5-72B-Instruct-AWQ • Confidence: HIGH
Is this CVE in your environment?
BreachSpider monitors your ICS/OT environment for vulnerabilities like this one. No agents or network access required. Free to start.
Check My Environment →What is CVE-2013-6920?
What is the CVSS score for CVE-2013-6920?
Is CVE-2013-6920 actively exploited?
How do I remediate CVE-2013-6920?
What systems are affected by CVE-2013-6920?
What NERC-CIP standard applies to CVE-2013-6920?
What IEC 62443 requirement maps to CVE-2013-6920?
| CVE ID | CVE-2013-6920 |
|---|---|
| BSID | BS-2013-GLOBAL-096477-C BreachSpider Global ID |
| CVSS Vector | AV:N/AC:L/Au:N/C:C/I:C/A:C |
| Published | 2013-12-07 |
| Last Modified | 2026-06-17 |
| ICS Relevance | 90% |
| Weakness (CWE) | |
| Verticals | |
| Source | NVD |
Siemens SINAMICS S/G controllers with firmware before 4.6.11 do not require authentication for FTP and TELNET sessions, which allows remote attackers to bypass intended access restrictions via TCP traffic to port (1) 21 or (2) 23.
Source: NIST NVD / MITRE CVE Database
Remote attackers can exploit this vulnerability by sending unauthenticated TCP traffic to ports 21 (FTP) and 23 (TELNET). The lack of authentication allows the attacker to gain full control over the affected controllers, potentially leading to unauthorized configuration changes, data exfiltration, and disruption of operations.
Exploitation Likelihood: LOW
| Vendor | Product | Affected Versions |
|---|---|---|
| Siemens | Sinamics G110 | No version listed by source |
| Siemens | Sinamics G110D | No version listed by source |
| Siemens | Sinamics G120 (device & firmware) | No version listed by source |
| Siemens | Sinamics G120C | No version listed by source |
| Siemens | Sinamics G120D | No version listed by source |
| Siemens | Sinamics G120P | No version listed by source |
| Siemens | Sinamics G130 (device & firmware) | No version listed by source |
| Siemens | Sinamics G150 (device & firmware) | No version listed by source |
| Siemens | Sinamics G180 | No version listed by source |
| Siemens | Sinamics S110 (device & firmware) | No version listed by source |
| Siemens | Sinamics S120 (device & firmware) | No version listed by source |
| Siemens | Sinamics S120CM | No version listed by source |
| Siemens | Sinamics S150 (device & firmware) | No version listed by source |
| Siemens | Sinamics S/G Family Firmware | < 4.6.11 |
| CISA known-exploited | Not in KEV catalog |
|---|---|
| Public Exploit | Not confirmed |
| PoC Code | Not confirmed |
Implement network segmentation and access controls to restrict access to the affected controllers. Use firewalls to block unauthorized access to ports 21 and 23 from untrusted networks.
No reliable network detection signature exists for this vulnerability class — apply the compensating controls above and the vendor patch. A network rule is only drafted when a concrete on-the-wire signature can be grounded in the advisory.
This CVE violates CIP-007-R2 because it allows unauthorized access to critical cyber assets, which can compromise the security and reliability of the power system.
This CVE maps to SR 7.6 as it involves the lack of proper authentication mechanisms, which is essential for protecting against unauthorized access to industrial control systems.
Drafted by AI and not validated for your network. Test in an isolated environment before any production deployment. Compensating control only - does not replace vendor patch.
AI Enrichment Record — provenance & audit hash
| Model | Qwen/Qwen2.5-72B-Instruct-AWQ |
|---|---|
| Confidence | HIGH |
| Enriched At | 2026-05-24 |
| SHA-512 Audit Hash | 86cb5bada685f438e2ae1c0d3f31a4e3f72bfc5d1f05d943df4357fefcf5837a36494d27ff3fbc3f1e69881d5f46b5d409eaa5d46c7876336f78fb5e5f0f00b5 |
Critical Severity - Know Your Exposure
A CVSS 10.0 vulnerability in your ICS environment cannot wait. BreachSpider maps critical CVEs to your specific assets and tells you what to fix first.
Create a free account →