CVE-2024-44102
A vulnerability has been identified in PP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 256 to 10...
Affects 1 product across 2 vendors.
Software deserializes untrusted data without validation, allowing crafted objects to execute arbitrary code.
Mapping is CWE-to-CAPEC per MITRE CAPEC 3.9.
A critical vulnerability (CVE-2024-44102) has been identified in multiple versions of PP TeleControl Server Basic and TeleControl Server Basic systems from Fujitsu-Siemens and Siemens. This vulnerability allows remote attackers to execute arbitrary code with SYSTEM privileges due to insecure deserialization of user-supplied content. All affected versions are prior to V3.1.2.1 when redundancy is configured. Immediate action is required to mitigate the risk of exploitation.
BSID: BS-2024-GLOBAL-211824-C • Model: Qwen/Qwen2.5-72B-Instruct-AWQ • Confidence: HIGH
Is this CVE in your environment?
BreachSpider monitors your ICS/OT environment for vulnerabilities like this one. No agents or network access required. Free to start.
Check My Environment →What is CVE-2024-44102?
What is the CVSS score for CVE-2024-44102?
Is CVE-2024-44102 actively exploited?
How do I remediate CVE-2024-44102?
What systems are affected by CVE-2024-44102?
What NERC-CIP standard applies to CVE-2024-44102?
What IEC 62443 requirement maps to CVE-2024-44102?
| CVE ID | CVE-2024-44102 |
|---|---|
| BSID | BS-2024-GLOBAL-211824-C BreachSpider Global ID |
| CVSS Vector | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H |
| Published | 2024-11-12 |
| Last Modified | 2024-11-13 |
| ICS Relevance | 70% |
| Weakness (CWE) | |
| Verticals | |
| Source | NVD |
A vulnerability has been identified in PP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 256 to 1000 V3.1 (6NH9910-0AA31-0AD1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 32 to 64 V3.1 (6NH9910-0AA31-0AF1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 64 to 256 V3.1 (6NH9910-0AA31-0AC1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 8 to 32 V3.1 (6NH9910-0AA31-0AB1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 1000 V3.1 (6NH9910-0AA31-0AD0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 256 V3.1 (6NH9910-0AA31-0AC0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 32 V3.1 (6NH9910-0AA31-0AF0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 5000 V3.1 (6NH9910-0AA31-0AE0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 64 V3.1 (6NH9910-0AA31-0AB0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 8 V3.1 (6NH9910-0AA31-0AA0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Serv Upgr (6NH9910-0AA31-0GA1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Upgr V3.1 (6NH9910-0AA31-0GA0) (All versions < V3.1.2.1 with redundancy configured). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges.
Source: NIST NVD / MITRE CVE Database
The vulnerability can be exploited remotely without authentication. An attacker can send a maliciously crafted serialized object to the affected system, leading to arbitrary code execution with SYSTEM privileges. This can result in complete compromise of the device, including data theft, system control, and further propagation of attacks within the network.
Exploitation Likelihood: CRITICAL
| Vendor | Product | Fixed Version |
|---|---|---|
| Fujitsu-Siemens | — | — |
| Siemens | Telecontrol Server Basic | — |
| CISA KEV | Not in KEV catalog |
|---|---|
| Public Exploit | Not confirmed |
| PoC Code | Not confirmed |
Implement strict input validation and sanitization for all incoming serialized objects. Use a secure deserialization library or framework that is designed to prevent such vulnerabilities. Consider deploying a Web Application Firewall (WAF) to filter out suspicious traffic.
No reliable network detection signature exists for this vulnerability class — apply the compensating controls above and the vendor patch. SAGE only publishes a network rule when a concrete on-the-wire signature can be grounded in the advisory.
This vulnerability violates CIP-007-R6 as it allows unauthorized access to the system, which can lead to the compromise of critical control systems and data. Immediate action is required to ensure compliance and protect against potential attacks.
This vulnerability maps to SR 7.6 because it involves the protection of the system against unauthorized access and manipulation. The insecure deserialization issue can lead to remote code execution, which is a significant threat to the security and integrity of the control system.
Virtual patch generated by CITED Relevance SAGE. Validate in isolated environment before production deployment. Compensating control only - does not replace vendor patch.
SAGE Enrichment Record — provenance & audit hash
| Model | Qwen/Qwen2.5-72B-Instruct-AWQ |
|---|---|
| Confidence | HIGH |
| Enriched At | 2026-05-24 |
| SHA-512 Audit Hash | 51ea76789b5e28a6d18dec92a618a105e20f4e745144bdb6322d9dfe5498d555bdff0173605be9c8e1b24560734441b787c208184c3312ec77236065934c8115 |
Critical Severity - Know Your Exposure
A CVSS 10.0 vulnerability in your ICS environment cannot wait. BreachSpider maps critical CVEs to your specific assets and tells you what to fix first.
Check Your Assets Free →